Equipment Technical Specification

Equipment Technical Specification

Prepared by: [YOUR NAME]


1. General Information

1.1 Equipment Name

Advanced Solar-Powered Generator

1.2 Manufacturer

SolarTech Industries

1.3 Model Number

STI-5000X

1.4 Year of Production

2060

1.5 Application

This equipment is designed for industrial-grade solar energy conversion, with the ability to provide uninterrupted power supply for large-scale operations, including manufacturing plants, data centers, and urban infrastructure.

1.6 Standards & Certifications

  • Complies with ISO 2060: Renewable Energy Systems

  • Certified under IEC 62109: Safety of Power Converters

  • UL 1741: Inverters, Converters, Controllers, and Interconnection System Equipment for Use with Distributed Energy Resources


2. Technical Specifications

2.1 Power Output

  • Nominal Output Power: 5000 kW

  • Peak Power: 5500 kW

  • Efficiency: 98%

  • AC Output Voltage: 400V, 3-phase, 50/60 Hz

  • DC Input Voltage Range: 400V – 800V

2.2 Battery Capacity

  • Battery Type: Lithium-Ion

  • Nominal Battery Capacity: 1000 kWh

  • Backup Duration: 12 hours at full load

  • Charging Time: 5 hours to 100%

  • Lifespan: 20 years or 10,000 cycles (whichever comes first)

2.3 Solar Input Specifications

  • Max Solar Input Voltage: 1000V DC

  • Maximum Input Current: 150A

  • Number of PV Arrays: 8 arrays, 250 kW each

  • Total Solar Input Capacity: 2000 kW

2.4 Environmental Parameters

  • Operating Temperature: -20°C to +60°C

  • Storage Temperature: -40°C to +85°C

  • Humidity: 0% – 95%, non-condensing

  • Protection Rating: IP66 (dustproof and waterproof)

  • Altitude: Up to 3000 meters without power derating


3. Construction & Design

3.1 Material Specifications

  • Frame: Corrosion-resistant stainless steel (Grade 316)

  • Enclosure: Aluminum with powder-coated finish

  • Cooling System: Liquid cooling with redundant fans

3.2 Weight & Dimensions

  • Weight: 5,500 kg

  • Dimensions:

    • Length: 5.2 meters

    • Width: 2.5 meters

    • Height: 2.8 meters

3.3 Mounting

  • Floor-mounted on vibration-dampening pads

  • Pre-drilled holes for ground anchoring


4. Electrical Characteristics

4.1 Efficiency and Losses

  • Total Harmonic Distortion (THD): ≤ 2%

  • Power Factor: 0.99 at full load

  • Inverter Efficiency: 97%

  • Standby Power Consumption: ≤ 50 W

4.2 Overload Capacity

  • 110% Overload: Continuous operation for 60 minutes

  • 125% Overload: 10 minutes

  • 150% Overload: 1 minute

4.3 Protection Features

  • Overvoltage and undervoltage protection

  • Short-circuit protection

  • Over-temperature shutdown

  • Ground fault monitoring

  • Surge protection (both AC and DC sides)


5. Safety and Compliance

5.1 Safety Features

  • Emergency Shutdown: Manual and remote-controlled shutdown mechanism

  • Fire Suppression: Integrated aerosol-based fire suppression system

  • Lockout/Tagout: Provisions for lockout/tagout during maintenance

  • Monitoring: Real-time monitoring for voltage, current, and temperature with alarm notifications

5.2 Certifications

  • CE Mark

  • UL 62109-1: Safety for Power Converters

  • IEC 61730: Photovoltaic Module Safety Qualification


6. Installation Requirements

6.1 Site Preparation

  • Foundation: Reinforced concrete platform, minimum thickness of 300mm

  • Grounding: Copper grounding rod system, resistance ≤ 5 ohms

  • Clearance: Minimum 1-meter clearance on all sides for ventilation

6.2 Electrical Connections

  • All electrical connections must be performed by a certified electrician.

  • Proper wiring and breaker sizing according to local electrical codes.

6.3 Tools and Equipment

  • Required: Torque wrench, thermal imaging camera, and insulation tester

  • Recommended: Data logger for real-time performance monitoring


7. Maintenance and Warranty

7.1 Routine Maintenance

  • Inspection Frequency: Quarterly inspections for electrical connections, temperature, and performance

  • Battery Maintenance: Replace after 10,000 cycles or 20 years

  • Cooling System: Check and replace coolant every 2 years

7.2 Troubleshooting Guide

  • Error Code E01: Overvoltage – Check PV input voltage

  • Error Code E02: Over-temperature – Inspect cooling system

  • Error Code E03: Ground fault – Check wiring and ground connections

7.3 Warranty

  • Standard Warranty: 10 years of parts and labor

  • Extended Warranty: Optional 15-year coverage for additional cost


8. Documentation and Support

8.1 Documentation

  • User Manual

  • Installation Guide

  • Maintenance Checklist

  • Troubleshooting Manual

8.2 Technical Support

  • 24/7 customer support hotline

  • Online technical support portal

  • Remote diagnostics and firmware updates are available via a secure connection

Technical Specification Templates @ Template.net